DWS-295 type of sodium ion concentration
Product Intro:
DWS-295-type sodium ion concentration of the main instrument for the power plant boiler feed water in addition to salt water, steam, condensation, water and other non-sample from the concentration of trace sodium determination; also can be used in institutions of higher learning, scientific research institutions, petro-chemical, microelectronics, etc. Determination of natural departments, boiler water, industrial drainage water samples, such as concentration of sodium ions.
Details:

Main technical indicators:

◆ Measurement Range: PNa values: (0.00 ~ 9.00) pNa

             [Na +] (concentration): (2.3 × 107 ~ 2.3 × 102) Цg / L

             Temperature: (-5.0 ~ 105.0) ℃

◆ fundamental error of electronic unit:

◆ pNa value: ± 0.01pNa ± 1 word

◆ pNa ~ [Na +] conversion calculation error: ± 3% (reading) ± 1 word

◆ Temperature: ± 0.3 ℃ ± 1 word

◆ Electronic Stability Unit: 0.01PNa ± 1 word / 3h

◆ Instrument Repeatability: pNa value: 0.02pNa ± 1 word

◆ measured solution temperature compensation range: (0.0 ~ 50.00) ℃

◆ Electronic unit dimensions mm: 290 × 200 × 75

◆ electronic unit weight: about 1Kg

◆ apparatus of normal working conditions:

    a) ambient temperature: (5 ~ 35) ℃;

    b) relative humidity: not more than 80%

    c) power supply: DC power supply (+9 V, 300mA, with positive and negative things)

    d) the measured temperature in aqueous solution: (0 ~ 50) ℃

    e) In addition to the surrounding magnetic over-the-counter, no other impact on the performance of the vibration of existence. 



 

There are a variety of specifications can not set out in detail, if necessary, are welcome to inquire.

 
HOT-
LINE
Huangneng of Daliang melts the glassy market: T:22261548 22281548 22263793  F:0757-22281548
Huangneng of Ronggui melts the glassy market: T:28810032 28810073 28810089  F:0757-28810089
 
 
         
Huaneng chemical all rights reserved, the prohibition of unauthorized copying reproduced or information site, and offenders held accountable by law